Check the Direct-drive cleaner head
		
				Step 1 - Removing the Direct-drive cleaner head from the wand
    - Disconnect the cleaner head from the wand by pressing the release button.
 
 
Step 2 - Unlocking the brushbar end cap
NB: Beware of sharp objects when checking for blockages.
    - If you cannot clear an obstruction you may need to remove the brushbar.
 
    - Use a coin to unlock the fastener marked with a padlock.
 
 
Step 3 - Removing the brushbar
NB: This product has carbon fibre brushes. Take care if coming into contact with them, as they may cause minor skin irritation. Wash your hands after handling the brushes.
    - Gently slide the brushbar away from the cleaner head.
 
 
Step 4 - Clear any debris 
    - Carefully clear any debris from the brushbar.
 
 
Step 5 - Refitting the brushbar
    - Slide the brushbar back onto the cleaner head, around the motor. The end cap should be in the open position as shown.
 
    - Once in place, rotate the end cap back into the closed position.
 
    - Close the fastener by turning a quarter turn clockwise. Ensure that the fastener is fully turned and the brushbar is secure.
 
    - Re-fit the cleaner head and test the machine.